United States Testing Company, Inc.Chemical Services Division
1415 Park Avenue, Hoboken, New Jersey 07030 Phone: 201-792-2400 Report of TestJune 26, 1990 - Test Number 035012 ClientCareChem Corporation SubjectOne wood panel submitted and identified by the client as: AuthorizationClient's letter of May 3, 1990. PurposeTo determine flame retadancy of the coating during accelerated weathering. ProcedureAccelerated weathering was accomplished by exposing the panel in a QUV Accelerated Weathering Tester maintained in accord with ASTM G-53. The Tester was programmed to alternate 4 hour periods of ultraviolet B at 60°C with 4 hour periods of water condensation at 50°C. After 500. 750 and 1000 hours of accelerated weathering the panel was tested for flame retardancy by holding a flame beneith the panel for 5 seconds and observing what happened. ResultsAfter 500 hours of accelerated weathering flame impingement caused the panel to flame for a few seconds. On the back where white deposit was still visible the flame went out at the deposit. On the front where the deposit was no longer visible the flame charred the surface for a few inches and the extinquished itself. |